• Run mains conduit in trench from house to garage • Run mains cable from main board in garage to distribution board in house (cable supplied - 25mm twin core with pilot) • Run telecoms conduit from house to power pole and install draw cord (with tee to garage, I need to run a single security cable from house to garage) • Run conduit from house to septic tank and install 2.5mm power supply from distribution board to septic • Run conduit from house to water tank and install 2.5mm power supply from distribution board for pump station Typical Waiheke site - reasonably steep with bush. approx 25m between house and garage. Other work available on same site, but unlike tasks listed above is not 'clean' - has been worked on previously by other Electrician and requires fixing. Trench is open now, looking for Electrician ASAP before rain wrecks the work done.